Standards
Standards & Interoperability
HealthOS ICU is designed around published international standards for medical device interoperability. No proprietary protocols are required in the primary integration path.
Architecture
Interoperability planes
Equipment
Equipment Plane
| Standard | Role | Conformance |
|---|---|---|
| HL7 v2 / MLLP | Inbound monitor stream ingestion | Implemented |
| IHE DEV / PCD (PCD-01, DEC, ACM) | Structured device data | Partial |
| ISO/IEEE 11073-10207 SDC | Bedside service-oriented control | Partial |
The control plane carries real-time telemetry from bedside devices. HL7 v2 over MLLP is the entry point for existing installations. An architectural slot for IHE PCD adapters enables structured device-data communication. The SDC write path (governed restricted-write control) is not part of HealthOS ICU v0 (pilot program): native bedside control remains on the roadmap, gated by phased validation and a vendor-supplied access-and-control package. Detailed status for each standard — in the conformance matrix →
Record
Record Plane
| Standard | Role | Conformance |
|---|---|---|
| FHIR R4 | Clinical data facade (results, audit, provenance) | Implemented |
| PROV-O | Provenance tracking in evidence-of-fact receipts | Implemented |
| SHACL | Knowledge graph constraint validation | Implemented |
FHIR R4 resources (Observation, Device, DeviceMetric, GuidanceResponse, Provenance, AuditEvent) are emitted by the clinical-data facade (a data projection for external systems) as a downstream projection of the canonical event log. FHIR is not the source of truth — the medical knowledge graph store (the source of truth, not FHIR) is.
PROV-O provides the provenance ontology for the evidence-of-fact receipt (proof of provenance): a cryptographic chain proving how a runtime artifact was derived from approved knowledge. SHACL validates the knowledge graph at compile time.
Auxiliary
Auxiliary Plane
| Standard | Role | Conformance |
|---|---|---|
| DICOMweb (WADO-RS / QIDO-RS) | Retrospective episode visualisation | Partial |
DICOMweb is used exclusively for retrospective episode review — loading waveform segments and correlating them with audit and result events for research and incident analysis. DICOM is not used as a command transport or stateful stream ingress.
Vendors
Vendor interoperability
The four-level adapter architecture accommodates vendors at any integration depth:
HL7 v2/MLLP ingest — any vendor with HL7 output.
IHE PCD profile mapping — vendors with PCD support.
ISO/IEEE 11073 SDC read path — SDC-capable devices.
ISO/IEEE 11073 SDC write path — phase 2, per-vendor validation pack.
Next
Documents
Technical Overview
Vendor interoperability, adapter architecture details
View →Conformance Matrix
Implemented, partial, planned — for each standard